Podatność CVE-2017-17436


Publikacja: 2017-12-06   Modyfikacja: 2017-12-07

Opis:
An issue was discovered in the software on Vaultek Gun Safe VT20i products. There is no encryption of the session between the Android application and the safe. The website and marketing materials advertise that this communication channel is encrypted with "Highest Level Bluetooth Encryption" and "Data transmissions are secure via AES256 bit encryption." These claims, however, are not true. Moreover, AES256 bit encryption is not supported in the Bluetooth Low Energy (BLE) standard, so it would have to be at the application level. This lack of encryption allows an individual to learn the passcode by eavesdropping on the communications between the application and the safe.

Typ:

CWE-326

(Inadequate Encryption Strength)

CVSS2 => (AV:A/AC:L/Au:N/C:P/I:N/A:N)

Ogólna skala CVSS
Znaczenie
Łatwość wykorzystania
3.3/10
2.9/10
6.5/10
Wymagany dostęp
Złożoność ataku
Autoryzacja
Sieć lokalna
Niska
Nie wymagana
Wpływ na poufność
Wpływ na integralność
Wpływ na dostępność
Częściowy
Brak
Brak
Affected software
Vaulteksafe -> Vt20i firmware 

 Referencje:
https://vaulteksafe.com/index.php/cve-2017-17435/
https://www.twosixlabs.com/bluesteal-popping-gatt-safes/