Podatność CVE-2017-6780
Publikacja: 2017-09-07 Modyfikacja: 2017-09-08
Opis: |
A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164. |
Typ:
CWE-770
CVSS2 => (AV:N/AC:L/Au:N/C:N/I:N/A:C)
Ogólna skala CVSS |
Znaczenie |
Łatwość wykorzystania |
7.8/10 |
6.9/10 |
10/10 |
Wymagany dostęp |
Złożoność ataku |
Autoryzacja |
Zdalny |
Niska |
Nie wymagana |
Wpływ na poufność |
Wpływ na integralność |
Wpływ na dostępność |
Brak |
Brak |
Pełny |
Referencje: |
http://www.securityfocus.com/bid/100641
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170906-fnd
|
|
|
closedb();
?>