Podatność CVE-2018-11457


Publikacja: 2018-12-12

Opis:
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known.

Typ:

CWE-noinfo

CVSS2 => (AV:N/AC:M/Au:N/C:C/I:C/A:C)

Ogólna skala CVSS
Znaczenie
Łatwość wykorzystania
9.3/10
10/10
8.6/10
Wymagany dostęp
Złożoność ataku
Autoryzacja
Zdalny
Średnia
Nie wymagana
Wpływ na poufność
Wpływ na integralność
Wpływ na dostępność
Pełny
Pełny
Pełny
Affected software
Siemens -> Sinumerik 828d v4.7 firmware 
Siemens -> Sinumerik 840d sl v4.7 firmware 
Siemens -> Sinumerik 840d sl v4.8 firmware 

 Referencje:
http://www.securityfocus.com/bid/106185
https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf

Copyright 2024, cxsecurity.com

 

Back to Top