Podatność CVE-2018-11463


Publikacja: 2018-12-12

Opis:
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Typ:

CWE-119

(Improper Restriction of Operations within the Bounds of a Memory Buffer)

CVSS2 => (AV:L/AC:L/Au:N/C:P/I:P/A:P)

Ogólna skala CVSS
Znaczenie
Łatwość wykorzystania
4.6/10
6.4/10
3.9/10
Wymagany dostęp
Złożoność ataku
Autoryzacja
Lokalny
Niska
Nie wymagana
Wpływ na poufność
Wpływ na integralność
Wpływ na dostępność
Częściowy
Częściowy
Częściowy
Affected software
Siemens -> Sinumerik 808d v4.7 firmware 
Siemens -> Sinumerik 808d v4.8 firmware 
Siemens -> Sinumerik 828d v4.7 firmware 
Siemens -> Sinumerik 840d sl v4.7 firmware 
Siemens -> Sinumerik 840d sl v4.8 firmware 

 Referencje:
http://www.securityfocus.com/bid/106185
https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf

Copyright 2024, cxsecurity.com

 

Back to Top