2012-11-23
 
CVE-2012-5864

CWE-264
 

 
The management web pages on the Sinapsi eSolar Light Photovoltaic System Monitor (aka Schneider Electric Ezylog photovoltaic SCADA management server), Sinapsi eSolar, and Sinapsi eSolar DUO with firmware before 2.0.2870_2.2.12 do not require authentication, which allows remote attackers to obtain administrative access via a direct request, as demonstrated by a request to ping.php.

 
 
CVE-2012-5863

CWE-264
 

 
ping.php on the Sinapsi eSolar Light Photovoltaic System Monitor (aka Schneider Electric Ezylog photovoltaic SCADA management server), Sinapsi eSolar, and Sinapsi eSolar DUO with firmware before 2.0.2870_2.2.12 allows remote attackers to execute arbitrary commands via shell metacharacters in the ip_dominio parameter.

 
 
CVE-2012-5862

CWE-310
 

 
login.php on the Sinapsi eSolar Light Photovoltaic System Monitor (aka Schneider Electric Ezylog photovoltaic SCADA management server), Sinapsi eSolar, and Sinapsi eSolar DUO with firmware before 2.0.2870_2.2.12 establishes multiple hardcoded accounts, which makes it easier for remote attackers to obtain administrative access by leveraging a (1) cleartext password or (2) password hash contained in this script, as demonstrated by a password of astridservice or 36e44c9b64.

 
 
CVE-2012-5861

CWE-89
 

 
Multiple SQL injection vulnerabilities on the Sinapsi eSolar Light Photovoltaic System Monitor (aka Schneider Electric Ezylog photovoltaic SCADA management server), Sinapsi eSolar, and Sinapsi eSolar DUO with firmware before 2.0.2870_2.2.12 allow remote attackers to execute arbitrary SQL commands via (1) the inverterselect parameter in a primo action to dettagliinverter.php or (2) the lingua parameter to changelanguagesession.php.

 