Index
Bugtraq
Pełna lista
Błędy
Sztuczki
Exploity
Dorks list
Tylko z CVE
Tylko z CWE
Bogus
Ranking
CVEMAP
Świeża lista CVE
Producenci
Produkty
Słownik CWE
Sprawdź nr. CVE
Sprawdź nr. CWE
Szukaj
W Bugtraq
W bazie CVE
Po autorze
Po nr. CVE
Po nr. CWE
Po producencie
Po produkcie
RSS
Bugtraq
CVEMAP
CVE Produkty
Tylko Błędy
Tylko Exploity
Tylko Dorks
Więcej
cIFrex
Facebook
Twitter
Donate
O bazie
Lang
Polish
English
Submit
Podatności dla
'Patient information center ix'
2020-09-11
CVE-2020-16224
CWE-130
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to restart.
CVE-2020-16220
CWE-1286
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling.
CVE-2020-16216
CWE-20
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.
CVE-2020-16212
CWE-668
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.
CVE-2020-16228
CWE-299
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.
CVE-2020-16222
CWE-287
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. When an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
CVE-2020-16218
CWE-79
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.
CVE-2020-16214
CWE-1236
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a command when the file is opened by spreadsheet software.
>>>
Vendor:
Philips
67
Produkty
Xper information management physiomonitoring 5
Xper information management vascular monitoring 5
Xperconnect
Xper flex cardio
In.sight b120\37
Hue bridge bsb002 firmware
Intellispace cardiovascular
Xcelera
Intellispace portal
Alice 6 firmware
Dosewise
brilliance ct big bore firmware
Brilliance firmware 64
Brilliance ict firmware
Brilliance ict sp firmware
Avalon fetal/maternal monitors fm20 firmware
Avalon fetal/maternal monitors fm30 firmware
Avalon fetal/maternal monitors fm40 firmware
Avalon fetal/maternal monitors fm50 firmware
Intellivue patient monitors mp2 firmware
Intellivue patient monitors mp30 firmware
Intellivue patient monitors mp50 firmware
Intellivue patient monitors mp70 firmware
Intellivue patient monitors mx100 firmware
Intellivue patient monitors mx400 firmware
Intellivue patient monitors mx450 firmware
Intellivue patient monitors mx500 firmware
Intellivue patient monitors mx550 firmware
Intellivue patient monitors mx700 firmware
Intellivue patient monitors mx800 firmware
Intellivue patient monitors np90 firmware
Intellivue patient monitors x2 firmware
Intellivue patient monitors x3 firmware
Smart control premium
Pagewriter tc10 firmware
Pagewriter tc20 firmware
Pagewriter tc30 firmware
Pagewriter tc50 firmware
Pagewriter tc70 firmware
E-alert firmware
Healthsuite health
Intellispace pacs
Isite pacs
Engage
Tasy emr
Zymed holter 2010
Hdi 4000 firmware
Intellivue mp monitors mp2/x2 firmware
Intellivue mp monitors mp20-mp90 firmware
Intellivue mp monitors mp5/5sc firmware
Intellivue mp monitors mx800/700/600 firmware
Tasy webportal
Smartcontrol
Dreammapper
Patient information center ix
Performancebridge focal point
Clinical collaboration platform
Coronary tools
Dynamic coronary roadmap
Interventional workspot
Stentboost live
Viewforum
Tasy electronic medical record
Myvue
Speech
Vue motion
Vue pacs
Copyright
2024
, cxsecurity.com
Back to Top