RSS   Podatności dla 'En100 ethernet module firmware'   RSS

2019-03-21
 
CVE-2018-16563

CWE-noinfo
 

 
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

 
2016-09-05
 
CVE-2016-7114

CWE-287
 

 
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.87; SIPROTEC 7UT686 : All versions < V 4.02; SIPROTEC 7SD686 : All versions < V 4.05; SIPROTEC 7SJ66 : All versions < V 4.30. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.

 
 
CVE-2016-7113

CWE-399
 

 
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode.

 
 
CVE-2016-7112

CWE-287
 

 
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations.

 

 >>> Vendor: Siemens 653 Produkty
Reliant unix
Hinet lp
3568i wap
M45
S45
S55
Santis 50
Speedstream wireless router
Gigaset se361 wlan router
Speedstream 6520
Speedstream 5200
Gigaset wlan camera
Gigaset c450 ip
Gigaset c475 ip
Gigaset se461 wimax router
Simatic pcs 7
Simatic wincc
Simatic wincc flexible runtime
Simatic wincc runtime
Tecnomatix factorylink
Simatic hmi panels
Wincc
Wincc flexible
Wincc flexible runtime
Wincc runtime advanced
Automation license manager
Scalance s firmware
Scalance s602
Scalance s612
Scalance s613
Scalance x-300 firmware
Scalance x-300eec firmware
Scalance x308-2m firmware
Scalance x414-3e firmware
Scalance xr-300 firmware
Scalance x-300
Scalance x-300eec
Scalance x308-2m
Scalance x414-3e
Scalance xr-300
Simatic pcs7
Simatic step 7
Simatic s7-400 cpu 412-2 pn
Simatic s7-400 cpu 414-3 pn/dp
Simatic s7-400 cpu 414f-3 pn/dp
Simatic s7-400 cpu 416-3 pn/dp
Simatic s7-400 cpu 416f-3 pn/dp
Simatic s7-400 cpu firmware
Synco ozw web server
Synco ozw web server firmware
Comos
Simatic s7-1200 plc
Sipass integrated
Processsuite
ROS
Rox i os
Rox ii os
Ruggedmax os
Simatic rf-manager
Simatic rf-manager 2008
Wincc tia portal
Scalance x204irt
Scalance x202-2irt
Scalance x202-2p irt
Scalance x201-3p irt
Scalance x200-4p irt
Scalance xf204irt
Scalance x200irt firmware
Openscape session border controller
Enterprise openscape branch
Scalance w744-1
Scalance w744-1pro
Scalance w746-1
Scalance w746-1pro
Scalance w747-1
Scalance w747-1rr
Scalance w784-1
Scalance w784-1rr
Scalance w786-1pro
Scalance w786-2pro
Scalance w786-2rr
Scalance w786-3pro
Scalance w788-1pro
Scalance w788-1rr
Scalance w788-2pro
Scalance w788-2rr
Scalance w700 series firmware
Scalance x-200
Scalance x-200rna
Scalance xf-200
Scalance x-200 series firmware
Sinamics g110
Sinamics g110d
Sinamics g120
Sinamics g120c
Sinamics g120d
Sinamics g120p
Sinamics g130
Sinamics g150
Sinamics g180
Zobacz wszystkie produkty dla producenta Siemens