RSS   Podatności dla 'Performancebridge focal point'   RSS

2020-09-11
 
CVE-2020-16220

CWE-1286
 

 
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling.

 
 
CVE-2020-16216

CWE-20
 

 
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.

 
 
CVE-2020-16228

CWE-299
 

 
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.

 
 
CVE-2020-16222

CWE-287
 

 
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. When an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.

 

 >>> Vendor: Philips 67 Produkty
Xper information management physiomonitoring 5
Xper information management vascular monitoring 5
Xperconnect
Xper flex cardio
In.sight b120\37
Hue bridge bsb002 firmware
Intellispace cardiovascular
Xcelera
Intellispace portal
Alice 6 firmware
Dosewise
brilliance ct big bore firmware
Brilliance firmware 64
Brilliance ict firmware
Brilliance ict sp firmware
Avalon fetal/maternal monitors fm20 firmware
Avalon fetal/maternal monitors fm30 firmware
Avalon fetal/maternal monitors fm40 firmware
Avalon fetal/maternal monitors fm50 firmware
Intellivue patient monitors mp2 firmware
Intellivue patient monitors mp30 firmware
Intellivue patient monitors mp50 firmware
Intellivue patient monitors mp70 firmware
Intellivue patient monitors mx100 firmware
Intellivue patient monitors mx400 firmware
Intellivue patient monitors mx450 firmware
Intellivue patient monitors mx500 firmware
Intellivue patient monitors mx550 firmware
Intellivue patient monitors mx700 firmware
Intellivue patient monitors mx800 firmware
Intellivue patient monitors np90 firmware
Intellivue patient monitors x2 firmware
Intellivue patient monitors x3 firmware
Smart control premium
Pagewriter tc10 firmware
Pagewriter tc20 firmware
Pagewriter tc30 firmware
Pagewriter tc50 firmware
Pagewriter tc70 firmware
E-alert firmware
Healthsuite health
Intellispace pacs
Isite pacs
Tasy emr
Zymed holter 2010
Hdi 4000 firmware
Intellivue mp monitors mp2/x2 firmware
Intellivue mp monitors mp20-mp90 firmware
Intellivue mp monitors mp5/5sc firmware
Intellivue mp monitors mx800/700/600 firmware
Tasy webportal
Smartcontrol
Dreammapper
Patient information center ix
Performancebridge focal point
Clinical collaboration platform
Coronary tools
Dynamic coronary roadmap
Interventional workspot
Stentboost live
Viewforum
Tasy electronic medical record
Engage
Myvue
Speech
Vue motion
Vue pacs


Copyright 2024, cxsecurity.com

 

Back to Top