Vulnerability CVE-2011-4878


Published: 2012-02-03   Modified: 2012-02-13

Description:
Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.

Vendor: Siemens
Product: Wincc 
Version: v11;
Product: Wincc runtime advanced 
Version: v11;
Product: Simatic hmi panels 
Version:
tp
op
mp
mobile_panels
comfort_panels
Product: Wincc flexible 
Version:
2008
2007
2005
2004
Product: Wincc flexible runtime 

CVSS2 => (AV:N/AC:L/Au:N/C:C/I:N/A:N)

CVSS Base Score
Impact Subscore
Exploitability Subscore
7.8/10
6.9/10
10/10
Exploit range
Attack complexity
Authentication
Remote
Low
No required
Confidentiality impact
Integrity impact
Availability impact
Complete
None
None

 References:
http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf
http://xforce.iss.net/xforce/xfdb/71452
http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf
http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf
http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf
http://www.osvdb.org/77383
http://www.exploit-db.com/exploits/18166
http://aluigi.org/adv/winccflex_1-adv.txt

Related CVE
CVE-2019-13935
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versi...
CVE-2019-13936
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a persistent XSS vulnerability. This issue affects: Siemens AG Polarion All vers...
CVE-2019-13934
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versi...
CVE-2019-13929
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access...
CVE-2019-13921
A vulnerability has been identified in SIMATIC WinAC RTX (F) 2010 (All versions). Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can b...
CVE-2019-10936
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO:...
CVE-2019-10923
A vulnerability has been identified in CP1604 (All versions < V2.8), CP1616 (All versions < V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET...
CVE-2019-13923
A vulnerability has been identified in IE/WSN-PA Link WirelessHART Gateway (All versions). The integrated configuration web server of the affected device could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing ...