Vulnerability CVE-2014-2732


Published: 2014-04-19   Modified: 2014-04-20

Description:
Multiple directory traversal vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to access arbitrary files via HTTP traffic to port (1) 4999 or (2) 80.

CVSS2 => (AV:N/AC:L/Au:N/C:P/I:N/A:N)

CVSS Base Score
Impact Subscore
Exploitability Subscore
5/10
2.9/10
10/10
Exploit range
Attack complexity
Authentication
Remote
Low
No required
Confidentiality impact
Integrity impact
Availability impact
Partial
None
None
Affected software
Siemens -> Sinema server 

 References:
http://ics-cert.us-cert.gov/advisories/ICSA-14-107-01
http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-364879.pdf
http://www.securityfocus.com/bid/66965

Copyright 2024, cxsecurity.com

 

Back to Top