Vulnerability CVE-2014-8385


Published: 2015-02-12   Modified: 2015-02-13

Description:
Buffer overflow on Advantech EKI-1200 gateways with firmware before 1.63 allows remote attackers to execute arbitrary code via unspecified vectors.

Type:

CWE-119

(Improper Restriction of Operations within the Bounds of a Memory Buffer)

Vendor: Advantech
Product: Eki-1200 gateway series firmware 
Version: 1.62;

CVSS2 => (AV:N/AC:L/Au:N/C:C/I:C/A:C)

CVSS Base Score
Impact Subscore
Exploitability Subscore
10/10
10/10
10/10
Exploit range
Attack complexity
Authentication
Remote
Low
No required
Confidentiality impact
Integrity impact
Availability impact
Complete
Complete
Complete

 References:
https://ics-cert.us-cert.gov/advisories/ICSA-15-041-01

Related CVE
CVE-2017-12705
A Heap-Based Buffer Overflow issue was discovered in Advantech WebOP. A maliciously crafted project file may be able to trigger a heap-based buffer overflow, which may crash the process and allow an attacker to execute arbitrary code.
CVE-2017-12717
An Uncontrolled Search Path Element issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. A maliciously crafted dll file placed earlier in the search path may allow an attacker to execute code within the context of the applicat...
CVE-2017-12713
An Incorrect Permission Assignment for Critical Resource issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Multiple files and folders with ACLs that affect other users are allowed to be modified by non-administrator account...
CVE-2017-12708
An Improper Restriction Of Operations Within The Bounds Of A Memory Buffer issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Researchers have identified multiple vulnerabilities that allow invalid locations to be referenced...
CVE-2017-12710
A SQL Injection issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. By submitting a specially crafted parameter, it is possible to inject arbitrary SQL statements that could allow an attacker to obtain sensitive information.
CVE-2017-12711
An Incorrect Privilege Assignment issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. A built-in user account has been granted a sensitive privilege that may allow a user to elevate to administrative privileges.
CVE-2017-12704
A heap-based buffer overflow issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Researchers have identified multiple vulnerabilities where there is a lack of proper validation of the length of user-supplied data prior to cop...
CVE-2017-12698
An Improper Authentication issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Specially crafted requests allow a possible authentication bypass that could allow remote code execution.