Vulnerability CVE-2015-2882
Published: 2017-04-09 Modified: 2017-04-10
Description: |
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account. |
CVSS2 => (AV:N/AC:L/Au:N/C:C/I:C/A:C)
CVSS Base Score |
Impact Subscore |
Exploitability Subscore |
10/10 |
10/10 |
10/10 |
Exploit range |
Attack complexity |
Authentication |
Remote |
Low |
No required |
Confidentiality impact |
Integrity impact |
Availability impact |
Complete |
Complete |
Complete |