Vulnerability CVE-2015-5441


Published: 2015-11-11   Modified: 2015-11-12

Description:
Multiple cross-site scripting (XSS) vulnerabilities in HP ArcSight Management Center before 2.1 and ArcSight Logger before 6.1 allow remote attackers to inject arbitrary web script or HTML via unspecified vectors.

Type:

CWE-79

(Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'))

Vendor: HP
Product: Arcsight logger 
Version: 6.0;
Product: Archsight management center 
Version: 2.0;

CVSS2 => (AV:N/AC:M/Au:N/C:N/I:P/A:N)

CVSS Base Score
Impact Subscore
Exploitability Subscore
4.3/10
2.9/10
8.6/10
Exploit range
Attack complexity
Authentication
Remote
Medium
No required
Confidentiality impact
Integrity impact
Availability impact
None
Partial
None

 References:
http://jvn.jp/en/jp/JVN51046809/index.html
http://jvndb.jvn.jp/en/contents/2015/JVNDB-2015-005909.html
http://www.securityfocus.com/archive/1/536877/100/0/threaded
https://h20564.www2.hpe.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c04797406

Related CVE
CVE-2019-6329
HP Support Assistant 8.7.50 and earlier allows a user to gain system privilege and allows unauthorized modification of directories or files. Note: A different vulnerability than CVE-2019-6328.
CVE-2019-6328
HP Support Assistant 8.7.50 and earlier allows a user to gain system privilege and allows unauthorized modification of directories or files. Note: A different vulnerability than CVE-2019-6329.
CVE-2019-11986
A remote code execution vulnerability was identified in HPE Intelligent Management Center (IMC) PLAT earlier than version 7.3 E0506P09.
CVE-2019-11985
A remote code execution vulnerability was identified in HPE Intelligent Management Center (IMC) PLAT earlier than version 7.3 E0506P09.
CVE-2019-11984
A SQL injection code execution vulnerability was identified in HPE Intelligent Management Center (IMC) PLAT earlier than version 7.3 E0506P09.
CVE-2019-11983
A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.
CVE-2019-11982
A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.
CVE-2019-11980
A remote code exection vulnerability was identified in HPE Intelligent Management Center (IMC) PLAT earlier than version 7.3 E0506P09.

Copyright 2019, cxsecurity.com

 

Back to Top