Vulnerability CVE-2016-9160


Published: 2016-12-16   Modified: 2016-12-17

Description:
A vulnerability in SIEMENS SIMATIC WinCC (All versions < SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions < SIMATIC PCS 7 V8.0 SP1) could allow a remote attacker to crash an ActiveX component or leak parts of the application memory if a user is tricked into clicking on a malicious link under certain conditions.

Vendor: Siemens
Product: Simatic pcs 7 
Version: 8.0;
Product: Simatic wincc 
Version: 7.1;

CVSS2 => (AV:N/AC:M/Au:N/C:P/I:N/A:P)

CVSS Base Score
Impact Subscore
Exploitability Subscore
5.8/10
4.9/10
8.6/10
Exploit range
Attack complexity
Authentication
Remote
Medium
No required
Confidentiality impact
Integrity impact
Availability impact
Partial
None
Partial

 References:
http://www.securityfocus.com/bid/94825
http://www.securitytracker.com/id/1037435
http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-693129.pdf
https://ics-cert.us-cert.gov/advisories/ICSA-16-348-04

Related CVE
CVE-2019-13929
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access...
CVE-2019-13921
A vulnerability has been identified in SIMATIC WinAC RTX (F) 2010 (All versions). Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can b...
CVE-2019-10936
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO:...
CVE-2019-10923
A vulnerability has been identified in CP1604 (All versions < V2.8), CP1616 (All versions < V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET...
CVE-2019-13923
A vulnerability has been identified in IE/WSN-PA Link WirelessHART Gateway (All versions). The integrated configuration web server of the affected device could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing ...
CVE-2019-13922
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attack...
CVE-2019-13920
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some parts of the web application are not protected against Cross Site Request Forgery (CSRF) attacks. The security vulnerability could be exploited by an ...
CVE-2019-13919
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some pages that should only be accessible by a privileged user can also be accessed by a non-privileged user. The security vulnerability could be exploited...

Copyright 2019, cxsecurity.com

 

Back to Top