An issue was discovered in the software on Vaultek Gun Safe VT20i products. There is no encryption of the session between the Android application and the safe. The website and marketing materials advertise that this communication channel is encrypted with "Highest Level Bluetooth Encryption" and "Data transmissions are secure via AES256 bit encryption." These claims, however, are not true. Moreover, AES256 bit encryption is not supported in the Bluetooth Low Energy (BLE) standard, so it would have to be at the application level. This lack of encryption allows an individual to learn the passcode by eavesdropping on the communications between the application and the safe.

Type:

CWE-326

(Inadequate Encryption Strength)

CVSS2 => (AV:A/AC:L/Au:N/C:P/I:N/A:N)

CVSS Base Score
Impact Subscore
Exploitability Subscore
3.3/10
2.9/10
6.5/10
Exploit range
Attack complexity
Authentication
Adjacent network
Low
No required
Confidentiality impact
Integrity impact
Availability impact
Partial
None
None
Affected software
Vaulteksafe -> Vt20i firmware 

 References:
https://vaulteksafe.com/index.php/cve-2017-17435/
https://www.twosixlabs.com/bluesteal-popping-gatt-safes/