Vulnerability CVE-2017-17704
Published: 2017-12-30 Modified: 2017-12-31
Description: |
A door-unlocking issue was discovered on Software House iStar Ultra devices through 6.5.2.20569 when used in conjunction with the IP-ACM Ethernet Door Module. The communications between the IP-ACM and the iStar Ultra is encrypted using a fixed AES key and IV. Each message is encrypted in CBC mode and restarts with the fixed IV, leading to replay attacks of entire messages. There is no authentication of messages beyond the use of the fixed AES key, so message forgery is also possible. |
Type:
CWE-330 (Use of Insufficiently Random Values)
CVSS2 => (AV:N/AC:M/Au:N/C:N/I:P/A:P)
CVSS Base Score |
Impact Subscore |
Exploitability Subscore |
5.8/10 |
4.9/10 |
8.6/10 |
Exploit range |
Attack complexity |
Authentication |
Remote |
Medium |
No required |
Confidentiality impact |
Integrity impact |
Availability impact |
None |
Partial |
Partial |
References: |
https://systemoverlord.com/2017/12/18/cve-2017-17704-broken-cryptography-in-istar-ultra-ip-acm-by-software-house.html
|
|
|
closedb();
?>