Vulnerability CVE-2018-10622


Published: 2018-08-10

Description:
A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected products use per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication and encryption of local data at rest.

Type:

CWE-255

(Credentials Management)

Vendor: Medtronic
Product: Mycarelink 24950 patient monitor firmware 
Product: Mycarelink 24952 patient monitor firmware 

CVSS2 => (AV:L/AC:M/Au:N/C:P/I:N/A:N)

CVSS Base Score
Impact Subscore
Exploitability Subscore
1.9/10
2.9/10
3.4/10
Exploit range
Attack complexity
Authentication
Local
Medium
No required
Confidentiality impact
Integrity impact
Availability impact
Partial
None
None

 References:
http://www.securityfocus.com/bid/105042
https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01

Related CVE
CVE-2018-10634
Medtronic MMT 508 MiniMed insulin pump, 522 / MMT - 722 Paradigm REAL-TIME, 523 / MMT - 723 Paradigm Revel, 523K / MMT - 723K Paradigm Revel, and 551 / MMT - 751 MiniMed 530G communications between the pump and wireless accessories are transmitted in...
CVE-2018-10626
A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected product's update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product cred...
CVE-2018-10631
Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programmer, all versions, and 8870 N'Vision removable Application Card, all versions. The 8840 Clinician Programmer executes the application program from the 8870 Application Card. An at...
CVE-2018-8870
Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to t...
CVE-2018-8868
Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions, contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between t...
CVE-2018-10596
Medtronic 2090 CareLink Programmer all versions The affected product uses a virtual private network connection to securely download updates. The product does not verify it is still connected to this virtual private network before downloading updates....
CVE-2018-8849
Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programmer, all versions, and 8870 N'Vision removable Application Card, all versions does not encrypt PII and PHI while at rest.
CVE-2018-5448
All versions of the Medtronic 2090 Carelink Programmer are affected by a directory traversal vulnerability where the product's software deployment network could allow an attacker to read files on the system.

Copyright 2018, cxsecurity.com

 

Back to Top