Vulnerability CVE-2018-10703


Published: 2019-06-07

Description:
An issue was discovered on Moxa AWK-3121 1.14 devices. It provides functionality so that an administrator can run scripts on the device to troubleshoot any issues. However, the same functionality allows an attacker to execute commands on the device. The POST parameter "iw_serverip" is susceptible to buffer overflow. By crafting a packet that contains a string of 480 characters, it is possible for an attacker to execute the attack.

See advisories in our WLB2 database:
Topic
Author
Date
Low
Moxa AWK-3121 1.14 Information Disclosure / Command Execution
Samuel Huntley
12.06.2019

Type:

CWE-119

(Improper Restriction of Operations within the Bounds of a Memory Buffer)

Vendor: MOXA
Product: Awk-3121 firmware 
Version: 1.14;

CVSS2 => (AV:N/AC:M/Au:N/C:P/I:P/A:P)

CVSS Base Score
Impact Subscore
Exploitability Subscore
6.8/10
6.4/10
8.6/10
Exploit range
Attack complexity
Authentication
Remote
Medium
No required
Confidentiality impact
Integrity impact
Availability impact
Partial
Partial
Partial

 References:
http://packetstormsecurity.com/files/153223/Moxa-AWK-3121-1.14-Information-Disclosure-Command-Execution.html
https://github.com/samuelhuntley/Moxa_AWK_1121/blob/master/Moxa_AWK_1121
https://seclists.org/bugtraq/2019/Jun/8

Related CVE
CVE-2018-11425
Memory corruption issue was discovered in Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11424.
CVE-2018-11424
There is Memory corruption in the web interface of Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11425.
CVE-2018-11423
There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420.
CVE-2018-11422
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be interc...
CVE-2018-11421
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercept...
CVE-2018-11420
There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423.
CVE-2018-11427
CSRF tokens are not used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior, which makes it possible to perform CSRF attacks on the device administrator.
CVE-2018-11426
A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functio...