Vulnerability CVE-2018-11421


Published: 2019-07-03

Description:
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator's password. Under certain conditions, it's also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages.

Type:

CWE-200

(Information Exposure)

CVSS2 => (AV:N/AC:L/Au:N/C:P/I:N/A:N)

CVSS Base Score
Impact Subscore
Exploitability Subscore
5/10
2.9/10
10/10
Exploit range
Attack complexity
Authentication
Remote
Low
No required
Confidentiality impact
Integrity impact
Availability impact
Partial
None
None
Affected software
MOXA -> Oncell g3150-hspa-t firmware 
MOXA -> Oncell g3150-hspa firmware 

 References:
https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-103.md

Copyright 2024, cxsecurity.com

 