Vulnerability CVE-2018-13806


Published: 2018-09-12

Description:
A vulnerability has been identified in SIEMENS TD Keypad Designer (All versions). A DLL hijacking vulnerability exists in all versions of SIEMENS TD Keypad Designer which could allow an attacker to execute code with the permission of the user running TD Designer. The attacker must have write access to the directory containing the TD project file in order to exploit the vulnerability. A legitimate user with higher privileges than the attacker must open the TD project in order for this vulnerability to be exploited. At the time of advisory publication no public exploitation of this security vulnerability was known.

Type:

CWE-427

(Uncontrolled Search Path Element)

CVSS2 => (AV:N/AC:M/Au:N/C:C/I:C/A:C)

CVSS Base Score
Impact Subscore
Exploitability Subscore
9.3/10
10/10
8.6/10
Exploit range
Attack complexity
Authentication
Remote
Medium
No required
Confidentiality impact
Integrity impact
Availability impact
Complete
Complete
Complete
Affected software
Siemens -> Td keypad designer 

 References:
https://cert-portal.siemens.com/productcert/pdf/ssa-198330.pdf