Vulnerability CVE-2018-4844


Published: 2018-03-20

Description:
A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Type:

CWE-269

(Improper Privilege Management)

CVSS2 => (AV:A/AC:M/Au:S/C:P/I:P/A:N)

CVSS Base Score
Impact Subscore
Exploitability Subscore
3.8/10
4.9/10
4.4/10
Exploit range
Attack complexity
Authentication
Adjacent network
Medium
Single time
Confidentiality impact
Integrity impact
Availability impact
Partial
Partial
None

 References:
http://www.securityfocus.com/bid/103475
https://cert-portal.siemens.com/productcert/pdf/ssa-822928.pdf
https://ics-cert.us-cert.gov/advisories/ICSA-18-081-01

Copyright 2024, cxsecurity.com

 