Vulnerability CVE-2019-10917


Published: 2019-05-14

Description:
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions), SIMATIC WinCC (TIA Portal) V15 (All versions), SIMATIC WinCC Runtime Professional (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 Upd3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Type:

CWE-20

(Improper Input Validation)

Vendor: Siemens
Product: Simatic pcs 7 
Version:
9.0
8.2
8.1
8.0
Product: Simatic wincc 
Version:
7.5
7.4
7.3
7.2
Product: Simatic wincc (tia portal) 
Version:
15.0
14.0
13.0
Product: Simatic wincc runtime professional 

CVSS2 => (AV:L/AC:L/Au:N/C:N/I:N/A:P)

CVSS Base Score
Impact Subscore
Exploitability Subscore
2.1/10
2.9/10
3.9/10
Exploit range
Attack complexity
Authentication
Local
Low
No required
Confidentiality impact
Integrity impact
Availability impact
None
None
Partial

 References:
http://www.securityfocus.com/bid/108404
https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf

Related CVE
CVE-2019-6578
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All...
CVE-2019-6577
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 un...
CVE-2019-6576
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 un...
CVE-2019-6574
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II co...
CVE-2019-6572
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 un...
CVE-2019-10924
A vulnerability has been identified in LOGO! Soft Comfort (All versions). The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. In order to exploit the vulnerabilit...
CVE-2019-10922
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network ac...
CVE-2019-10921
A vulnerability has been identified in LOGO!8 BM (All versions). Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by...