Vulnerability CVE-2019-10927


Published: 2019-08-13

Description:
A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the availability of the affected device.

Type:

CWE-20

(Improper Input Validation)

Vendor: Siemens
Product: Scalance xb-200 firmware 
Version: 4.1;
Product: Scalance xf-200ba firmware 
Version: 4.1;
Product: Scalance xr-300wg firmware 
Version: 4.1;
Product: Scalance xc-200 firmware 
Version: 4.1;
Product: Scalance xp-200 firmware 
Version: 4.1;

CVSS2 => (AV:N/AC:L/Au:S/C:N/I:N/A:P)

CVSS Base Score
Impact Subscore
Exploitability Subscore
4/10
2.9/10
8/10
Exploit range
Attack complexity
Authentication
Remote
Low
Single time
Confidentiality impact
Integrity impact
Availability impact
None
None
Partial

 References:
https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf

Related CVE
CVE-2019-13935
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versi...
CVE-2019-13936
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a persistent XSS vulnerability. This issue affects: Siemens AG Polarion All vers...
CVE-2019-13934
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versi...
CVE-2019-13929
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access...
CVE-2019-13921
A vulnerability has been identified in SIMATIC WinAC RTX (F) 2010 (All versions). Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can b...
CVE-2019-10936
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO:...
CVE-2019-10923
A vulnerability has been identified in CP1604 (All versions < V2.8), CP1616 (All versions < V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET...
CVE-2019-13923
A vulnerability has been identified in IE/WSN-PA Link WirelessHART Gateway (All versions). The integrated configuration web server of the affected device could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing ...