Vulnerability CVE-2019-10930


Published: 2019-07-11

Description:
A vulnerability has been identified in SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions), DIGSI 5 engineering software (All versions < V7.90). A remote attacker could use specially crafted packets sent to port 443/TCP to upload, download or delete files in certain parts of the file system.

Type:

CWE-434

(Unrestricted Upload of File with Dangerous Type)

Vendor: Siemens
Product: Digsi 5 engineering software 
Version: 7.90;
Product: Siprotec 5 digsi device driver 
Version: 7.90;

CVSS2 => (AV:N/AC:L/Au:N/C:N/I:P/A:P)

CVSS Base Score
Impact Subscore
Exploitability Subscore
6.4/10
4.9/10
10/10
Exploit range
Attack complexity
Authentication
Remote
Low
No required
Confidentiality impact
Integrity impact
Availability impact
None
Partial
Partial

 References:
https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf

Related CVE
CVE-2019-13935
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versi...
CVE-2019-13936
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a persistent XSS vulnerability. This issue affects: Siemens AG Polarion All vers...
CVE-2019-13934
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versi...
CVE-2019-13929
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access...
CVE-2019-13921
A vulnerability has been identified in SIMATIC WinAC RTX (F) 2010 (All versions). Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can b...
CVE-2019-10936
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO:...
CVE-2019-10923
A vulnerability has been identified in CP1604 (All versions < V2.8), CP1616 (All versions < V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET...
CVE-2019-13923
A vulnerability has been identified in IE/WSN-PA Link WirelessHART Gateway (All versions). The integrated configuration web server of the affected device could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing ...

Copyright 2019, cxsecurity.com

 