Vulnerability CVE-2019-12310
Published: 2019-06-03
Description: |
ExaGrid appliances with firmware version v4.8.1.1044.P50 have a /monitor/data/Upgrade/ directory traversal vulnerability, which allows remote attackers to view and retrieve verbose logging information. Files within this directory were observed to contain sensitive run-time information, including Base64 encoded 'support' credentials, leading to administrative access of the device. |
Type:
CWE-22 (Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'))
CVSS2 => (AV:N/AC:L/Au:N/C:P/I:N/A:N)
CVSS Base Score |
Impact Subscore |
Exploitability Subscore |
5/10 |
2.9/10 |
10/10 |
Exploit range |
Attack complexity |
Authentication |
Remote |
Low |
No required |
Confidentiality impact |
Integrity impact |
Availability impact |
Partial |
None |
None |
References: |
https://exagrid.com/exagrid-products/resources/
https://www.inquisitllc.com/exagrid-directory-traversal-vulnerability-to-support-credential-extraction/
|
|
|