Vulnerability CVE-2019-13919


Published: 2019-09-13

Description:
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some pages that should only be accessible by a privileged user can also be accessed by a non-privileged user. The security vulnerability could be exploited by an attacker with network access and valid credentials for the web interface. No user interaction is required. The vulnerability could allow an attacker to access information that he should not be able to read. The affected information does not include passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.

Type:

CWE-200

(Information Exposure)

Vendor: Siemens
Product: Sinema remote connect server 
Version: 2.0;

CVSS2 => (AV:N/AC:L/Au:S/C:P/I:N/A:N)

CVSS Base Score
Impact Subscore
Exploitability Subscore
4/10
2.9/10
8/10
Exploit range
Attack complexity
Authentication
Remote
Low
Single time
Confidentiality impact
Integrity impact
Availability impact
Partial
None
None

 References:
https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf

Related CVE
CVE-2019-13929
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access...
CVE-2019-13921
A vulnerability has been identified in SIMATIC WinAC RTX (F) 2010 (All versions). Affected versions of the software contain a vulnerability that could allow an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can b...
CVE-2019-10936
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO:...
CVE-2019-10923
A vulnerability has been identified in CP1604 (All versions < V2.8), CP1616 (All versions < V2.8), Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions < V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET...
CVE-2019-13923
A vulnerability has been identified in IE/WSN-PA Link WirelessHART Gateway (All versions). The integrated configuration web server of the affected device could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing ...
CVE-2019-13922
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attack...
CVE-2019-13920
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some parts of the web application are not protected against Cross Site Request Forgery (CSRF) attacks. The security vulnerability could be exploited by an ...
CVE-2019-13918
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnera...

Copyright 2019, cxsecurity.com

 

Back to Top