Vulnerability CVE-2019-19298
Published: 2020-03-10
Description: |
A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR 3 Video Server (all versions). The streaming service (default port 5410/tcp) of the SiNVR 3 Video Server contains a input validation vulnerability, that could allow an unauthenticated remote attacker to cause a Denial-of-Service condition by sending malformed HTTP requeats. |
Type:
CWE-20 (Improper Input Validation)
CVSS2 => (AV:N/AC:L/Au:N/C:N/I:N/A:P)
CVSS Base Score |
Impact Subscore |
Exploitability Subscore |
5/10 |
2.9/10 |
10/10 |
Exploit range |
Attack complexity |
Authentication |
Remote |
Low |
No required |
Confidentiality impact |
Integrity impact |
Availability impact |
None |
None |
Partial |
References: |
https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf
|
|
|