Vulnerability CVE-2020-6768


Published: 2020-02-07   Modified: 2020-02-08

Description:
A path traversal vulnerability in the Bosch Video Management System (BVMS) NoTouch deployment allows an unauthenticated remote attacker to read arbitrary files from the Central Server. This affects Bosch BVMS versions 10.0 <= 10.0.0.1225, 9.0 <= 9.0.0.827, 8.0 <= 8.0.329 and 7.5 and older. This affects Bosch BVMS Viewer versions 10.0 <= 10.0.0.1225, 9.0 <= 9.0.0.827, 8.0 <= 8.0.329 and 7.5 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable BVMS version is installed.

Type:

CWE-22

(Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'))

CVSS2 => (AV:N/AC:L/Au:N/C:P/I:N/A:N)

CVSS Base Score
Impact Subscore
Exploitability Subscore
5/10
2.9/10
10/10
Exploit range
Attack complexity
Authentication
Remote
Low
No required
Confidentiality impact
Integrity impact
Availability impact
Partial
None
None
Affected software
Bosch -> Video management system viewer 

 References:
https://psirt.bosch.com/security-advisories/bosch-sa-815013-bt.html