Vulnerability CVE-2021-27471


Published: 2022-03-23

Description:
The parsing mechanism that processes certain file types does not provide input sanitization for file paths. This may allow an attacker to craft malicious files that, when opened by Rockwell Automation Connected Components Workbench v12.00.00 and prior, can traverse the file system. If successfully exploited, an attacker could overwrite existing files and create additional files with the same permissions of the Connected Components Workbench software. User interaction is required for this exploit to be successful.

Type:

CWE-22

(Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'))

CVSS2 => (AV:N/AC:M/Au:N/C:P/I:P/A:P)

CVSS Base Score
Impact Subscore
Exploitability Subscore
6.8/10
6.4/10
8.6/10
Exploit range
Attack complexity
Authentication
Remote
Medium
No required
Confidentiality impact
Integrity impact
Availability impact
Partial
Partial
Partial
Affected software
Rockwellautomation -> Connected components workbench 

 References:
https://www.cisa.gov/uscert/ics/advisories/icsa-21-133-01
https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1131435

Copyright 2024, cxsecurity.com

 