Vulnerability CVE-2021-38393
Published: 2021-08-30
Description: |
A Blind SQL injection vulnerability exists in the /DataHandler/HandlerAlarmGroup.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter agid before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER. |
Type:
CWE-89 (Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'))
CVSS2 => (AV:N/AC:L/Au:N/C:C/I:C/A:C)
CVSS Base Score |
Impact Subscore |
Exploitability Subscore |
10/10 |
10/10 |
10/10 |
Exploit range |
Attack complexity |
Authentication |
Remote |
Low |
No required |
Confidentiality impact |
Integrity impact |
Availability impact |
Complete |
Complete |
Complete |
References: |
https://us-cert.cisa.gov/ics/advisories/icsa-21-238-03
|
|
|