Vulnerability CVE-2021-39375


Published: 2021-08-24

Description:
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the WAdvancedFilter/getDimensionItemsByCode FilterValue parameter.

Type:

CWE-89

(Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'))

CVSS2 => (AV:N/AC:L/Au:S/C:P/I:P/A:P)

CVSS Base Score
Impact Subscore
Exploitability Subscore
6.5/10
6.4/10
8/10
Exploit range
Attack complexity
Authentication
Remote
Low
Single time
Confidentiality impact
Integrity impact
Availability impact
Partial
Partial
Partial
Affected software
Philips -> Tasy electronic medical record 