Vulnerability CVE-2022-23450


Published: 2022-04-12

Description:
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.

Type:

CWE-502

(Deserialization of Untrusted Data)

CVSS2 => (AV:N/AC:L/Au:N/C:C/I:C/A:C)

CVSS Base Score
Impact Subscore
Exploitability Subscore
10/10
10/10
10/10
Exploit range
Attack complexity
Authentication
Remote
Low
No required
Confidentiality impact
Integrity impact
Availability impact
Complete
Complete
Complete
Affected software
Siemens -> Simatic energy manager basic 
Siemens -> Simatic energy manager pro 

 References:
https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf