Vulnerability CVE-2022-23450
Published: 2022-04-12
| Description: |
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges. |
Type:
CWE-502 (Deserialization of Untrusted Data)
CVSS2 => (AV:N/AC:L/Au:N/C:C/I:C/A:C)
| CVSS Base Score |
Impact Subscore |
Exploitability Subscore |
10/10 |
10/10 |
10/10 |
| Exploit range |
Attack complexity |
Authentication |
Remote |
Low |
No required |
| Confidentiality impact |
Integrity impact |
Availability impact |
Complete |
Complete |
Complete |
References: |
https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf
|
|
|