Index
Bugtraq
Pełna lista
Błędy
Sztuczki
Exploity
Dorks list
Tylko z CVE
Tylko z CWE
Bogus
Ranking
CVEMAP
Świeża lista CVE
Producenci
Produkty
Słownik CWE
Sprawdź nr. CVE
Sprawdź nr. CWE
Szukaj
W Bugtraq
W bazie CVE
Po autorze
Po nr. CVE
Po nr. CWE
Po producencie
Po produkcie
RSS
Bugtraq
CVEMAP
CVE Produkty
Tylko Błędy
Tylko Exploity
Tylko Dorks
Więcej
cIFrex
Facebook
Twitter
Donate
O bazie
Lang
Polish
English
Submit
CWE
:
Nic nie znaleziono w bazie WLB2
Common Weakness Enumeration (CWE)
CVE
Szczegóły
Opis
2022-12-28
CVE-2022-46173
Updating...
Elrond-GO is a go implementation for the Elrond Network protocol. Versions prior to 1.3.50 are subject to a processing issue where nodes are affected when trying to process a cross-shard relayed transaction with a smart contract deploy transaction data. The problem was a bad correlation between the transaction caches and the processing component. If the above-mentioned transaction was sent with more gas than required, the smart contract result (SCR transaction) that should have returned the leftover gas, would have been wrongly added to a cache that the processing unit did not consider. The node stopped notarizing metachain blocks. The fix was actually to extend the SCR transaction search in all other caches if it wasn't found in the correct (expected) sharded-cache. There are no known workarounds at this time. This issue has been patched in version 1.3.50.
2022-09-23
CVE-2022-39225
Updating...
Parse Server is an open source backend that can be deployed to any infrastructure that can run Node.js. In versions prior to 4.10.15, or 5.0.0 and above prior to 5.2.6, a user can write to the session object of another user if the session object ID is known. For example, an attacker can assign the session object to their own user by writing to the `user` field and then read any custom fields of that session object. Note that assigning a session to another user does not usually change the privileges of either of the two users, and a user cannot assign their own session to another user. This issue is patched in version 4.10.15 and above, and 5.2.6 and above. To mitigate this issue in unpatched versions add a `beforeSave` trigger to the `_Session` class and prevent writing if the requesting user is different from the user in the session object.
2022-06-02
CVE-2022-30236
Updating...
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
2022-02-11
CVE-2021-22806
Updating...
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)
2022-01-21
Medium
CVE-2021-36338
Vendor:
DELL
Software:
Solutions en...
Unisphere for PowerMax versions prior to 9.2.2.2 contains a privilege escalation vulnerability. An adjacent malicious user could potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to.
2022-01-14
High
CVE-2022-20658
Vendor:
Cisco
Software:
Unified cont...
A vulnerability in the web-based management interface of Cisco Unified Contact Center Management Portal (Unified CCMP) and Cisco Unified Contact Center Domain Manager (Unified CCDM) could allow an authenticated, remote attacker to elevate their privileges to Administrator. This vulnerability is due to the lack of server-side validation of user permissions. An attacker could exploit this vulnerability by submitting a crafted HTTP request to a vulnerable system. A successful exploit could allow the attacker to create Administrator accounts. With these accounts, the attacker could access and modify telephony and user resources across all the Unified platforms that are associated to the vulnerable Cisco Unified CCMP. To successfully exploit this vulnerability, an attacker would need valid Advanced User credentials.
2021-08-02
Low
CVE-2021-34574
Vendor:
Mbconnectline
Software:
Mbconnect24
In MB connect line mymbCONNECT24, mbCONNECT24 in versions <= 2.8.0 an authenticated attacker can change the password of his account into a new password that violates the password policy by intercepting and modifying the request that is send to the server.
2021-06-24
Low
CVE-2021-29960
Vendor:
Mozilla
Software:
Firefox
Firefox used to cache the last filename used for printing a file. When generating a filename for printing, Firefox usually suggests the web page title. The caching and suggestion techniques combined may have lead to the title of a website visited during private browsing mode being stored on disk. This vulnerability affects Firefox < 89.
2021-02-12
Medium
CVE-2021-20411
Updating...
IBM Security Verify Information Queue 1.0.6 and 1.0.7 could allow a user to impersonate another user on the system due to incorrectly updating the session identifier. IBM X-Force ID: 198191.
2020-12-22
Medium
CVE-2020-24683
Vendor:
ABB
Software:
Symphony plu...
The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at the client node (client-side authentication). This is not as secure as having the server validate a client application before allowing a connection. Therefore, if the network communication or endpoints for these applications are not protected, unauthorized actors can bypass authentication and make unauthorized connections to the server application.
Copyright
2024
, cxsecurity.com
Back to Top