Podatność CVE-2023-48431


Publikacja: 2023-12-12   Modyfikacja: 2023-12-14

Opis:
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected software does not correctly validate the response received by an UMC server. An attacker can use this to crash the affected software by providing and configuring a malicious UMC server or by manipulating the traffic from a legitimate UMC server (i.e. leveraging CVE-2023-48427).

Typ:

CWE-754

Affected software
Siemens -> Sinec ins 

 Referencje:
https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf