RSS   Vulnerabilities for
'Interactive graphical scada system data server'
   RSS

2022-02-09
 
CVE-2022-24310

CWE-190
 

 
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

 
 
CVE-2022-24311

CWE-22
 

 
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

 
 
CVE-2022-24312

CWE-22
 

 
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

 
 
CVE-2022-24313

CWE-120
 

 
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

 
 
CVE-2022-24314

CWE-125
 

 
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

 
 
CVE-2022-24315

CWE-125
 

 
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

 
 
CVE-2022-24316

CWE-665
 

 
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

 
 
CVE-2022-24317

CWE-862
 

 
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

 

 >>> Vendor: Schneider-electric 299 Products
Power manager
Software update
Citectfacilities
Citectscada
Clearscada 2005
Clearscada 2007
Clearscada 2009
Monitor pro
Opc factory server
Pl7 pro
Telemecanique driver pack
Unity pro
Vijeo citect
Citecthistorian
Citectscada reports
Vijeo historian
M340 ethernet module bmxnoe0100
M340 ethernet module bmxnoe0110
M340 ethernet module bmxp342020
M340 ethernet module bmxp342030
Premium ethernet module tsxety4103
Premium ethernet module tsxety5103
Premium ethernet module tsxp57163m
Premium ethernet module tsxp572634m
Premium ethernet module tsxp573634m
Premium ethernet module tsxp574634m
Premium ethernet module tsxp575634m
Premium ethernet module tsxp576634m
Quantum ethernet module 140cpu65150
Quantum ethernet module 140cpu65160
Quantum ethernet module 140cpu65260
Quantum ethernet module 140noe77100
Quantum ethernet module 140noe77101
Quantum ethernet module 140noe77111
Stb dio ethernet module stbnic2212
Stb dio ethernet module stbnip2212
Stb dio ethernet module stbnip2311
Modicon quantum plc
Wonderware historian
Wonderware intouch
Software update utility
Interactive graphical scada system
Accutech manager
Modicon m340
Modicon premium
Magelis xbt hmi
Micom s1 studio
Kerweb
Kerwin
Tburjr900
Tburjr900 firmware
Clearscada
Scada expert clearscada
Telvent sage 3030
Telvent sage 3030 firmware
Struxureware scada expert vijeo citect
Struxureware powerscada expert
Powerlogic scada
Floating license manager
Ofs test client tlxcdlfofs33
Ofs test client tlxcdltofs33
Ofs test client tlxcdluofs33
Ofs test client tlxcdstofs33
Ofs test client tlxcdsuofs33
Concept
Modbus serial driver
Modbuscommdtm sl
PL7
Powersuite
Sft2841
Somachine
Somove
Twidosuite
Unityloader
Opc factory server tlxcdlfofs
Opc factory server tlxcdltofs
Opc factory server tlxcdluofs
Opc factory server tlxcdstofs
Opc factory server tlxcdsuofs
Vampset
Modicon plc ethernet module
Proclima
Wonderware intouch access anywhere server
Tsxetg3000
Tsxetg3010
Tsxetg3021
Tsxetg3022
Etg3000 factorycast hmi gateway firmware
Somove lite
Device type manager
Indusoft web studio
Wonderware intouch 2014
Wonderware system platform 2014
Imt25 magnetic flow dtm
Bmxnoc0401
Bmxnoe0100
Bmxnoe0100h
Bmxnoe0110
Bmxnoe0110h
Bmxnor0200
See all Products for Vendor Schneider-electric


Copyright 2024, cxsecurity.com

 

Back to Top