Vulnerability CVE-2017-5598


Published: 2017-01-27

Description:
An issue was discovered in eClinicalWorks healow@work 8.0 build 8. This is a blind SQL injection within the EmployeePortalServlet, which can be exploited by un-authenticated users via an HTTP POST request and which can be used to dump database data out to a malicious server, using an out-of-band technique, such as select_loadfile(). The vulnerability affects the EmployeePortalServlet page and the following parameter: employer.

CVSS2 => (AV:N/AC:L/Au:N/C:P/I:N/A:N)

CVSS Base Score
Impact Subscore
Exploitability Subscore
5/10
2.9/10
10/10
Exploit range
Attack complexity
Authentication
Remote
Low
No required
Confidentiality impact
Integrity impact
Availability impact
Partial
None
None
Affected software
Eclinicalworks -> Patient portal 

 References:
http://www.securityfocus.com/bid/95836
https://gist.github.com/malerisch/ded4d6e6e980667ee9f7fc7f2818f4fa