Vulnerability CVE-2017-9857


Published: 2017-08-05

Description:
** DISPUTED ** An issue was discovered in SMA Solar Technology products. The SMAdata2+ communication protocol does not properly use authentication with encryption: it is vulnerable to man in the middle, packet injection, and replay attacks. Any setting change, authentication packet, scouting packet, etc. can be replayed, injected, or used for a man in the middle session. All functionalities available in Sunny Explorer can effectively be done from anywhere within the network as long as an attacker gets the packet setup correctly. This includes the authentication process for all (including hidden) access levels and the changing of settings in accordance with the gained access rights. Furthermore, because the SMAdata2+ communication channel is unencrypted, an attacker capable of understanding the protocol can eavesdrop on communications. NOTE: the vendor's position is that authentication with encryption is not required on an isolated subnetwork. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected.

CVSS2 => (AV:N/AC:M/Au:N/C:P/I:N/A:N)

CVSS Base Score
Impact Subscore
Exploitability Subscore
4.3/10
2.9/10
8.6/10
Exploit range
Attack complexity
Authentication
Remote
Medium
No required
Confidentiality impact
Integrity impact
Availability impact
Partial
None
None
Affected software
SMA -> Sunny boy 5000 firmware 
SMA -> Sunny central 800cp xt firmware 
SMA -> Sunny central storage 1000 firmware 
SMA -> Sunny central storage 760 firmware 
SMA -> Sunny boy 3000tl firmware 
SMA -> Sunny boy 4000tl firmware 
SMA -> Sunny boy 5.0 firmware 
SMA -> Sunny tripower 25000tl firmware 
SMA -> Sunny central storage 2200 firmware 
SMA -> Sunny tripower 12000tl firmware 
SMA -> Sunny central 630cp xt firmware 
SMA -> Sunny boy 2.5 firmware 
SMA -> Sunny central storage 630 firmware 
SMA -> Sunny boy 4.0 firmware 
SMA -> Sunny boy 3.6 firmware 
SMA -> Sunny central storage 500 firmware 
SMA -> Sunny central 500cp xt firmware 
SMA -> Sunny central 1000cp xt firmware 
SMA -> Sunny central 850cp xt firmware 
SMA -> Sunny central storage 800 firmware 
SMA -> Sunny central 900cp xt firmware 
SMA -> Sunny tripower 20000tl firmware 
SMA -> Sunny central storage 900 firmware 
SMA -> Sunny tripower core1 firmware 
SMA -> Sunny boy 5000tl firmware 
SMA -> Sunny tripower 5000tl firmware 
SMA -> Sunny boy storage 2.5 firmware 
SMA -> Sunny central 2200 firmware 
SMA -> Sunny central storage 720 firmware 
SMA -> Sunny central 760cp xt firmware 
SMA -> Sunny boy 3600tl firmware 
SMA -> Sunny central 720cp xt firmware 
SMA -> Sunny central storage 2500-ev firmware 
SMA -> Sunny boy 1.5 firmware 
SMA -> Sunny boy 3.0 firmware 
SMA -> Sunny boy 3600 firmware 
SMA -> Sunny tripower 15000tl firmware 
SMA -> Sunny tripower 60 firmware 
SMA -> Sunny central storage 850 firmware 