Vulnerability CVE-2018-10594
Published: 2018-06-26
Description: |
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server. |
See advisories in our WLB2 database: | Topic | Author | Date |
High |
| t4rkd3vilz | 02.07.2018 |
Type:
CWE-119 (Improper Restriction of Operations within the Bounds of a Memory Buffer)
CVSS2 => (AV:N/AC:L/Au:N/C:P/I:P/A:P)
CVSS Base Score |
Impact Subscore |
Exploitability Subscore |
7.5/10 |
6.4/10 |
10/10 |
Exploit range |
Attack complexity |
Authentication |
Remote |
Low |
No required |
Confidentiality impact |
Integrity impact |
Availability impact |
Partial |
Partial |
Partial |
References: |
http://www.securityfocus.com/bid/104529
https://ics-cert.us-cert.gov/advisories/ICSA-18-172-01
https://www.exploit-db.com/exploits/44965/
https://www.exploit-db.com/exploits/45574/
|
|
|
closedb();
?>