Vulnerability CVE-2018-13812


Published: 2018-12-13

Description:
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Type:

CWE-22

(Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'))

Vendor: Siemens
Product: Simatic hmi ktp mobile panels ktp700 firmware 
Version: 15.0;
Product: Simatic wincc (tia portal) 
Version: 15.0;
Product: Simatic hmi ktp mobile panels ktp900 firmware 
Version: 15.0;
Product: Simatic hmi comfort outdoor panels firmware 
Version: 15.0;
Product: Simatic hmi ktp mobile panels ktp400f firmware 
Version: 15.0;
Product: Simatic hmi ktp mobile panels ktp700f firmware 
Version: 15.0;
Product: Simatic wincc runtime 
Version: 15.0;
Product: Simatic hmi ktp mobile panels ktp900f firmware 
Version: 15.0;
Product: Simatic hmi comfort panels firmware 
Version: 15.0;
Product: Simatic hmi mp firmware 
Product: Simatic hmi tp firmware 
Product: Simatic hmi op firmware 

CVSS2 => (AV:N/AC:L/Au:N/C:P/I:N/A:N)

CVSS Base Score
Impact Subscore
Exploitability Subscore
5/10
2.9/10
10/10
Exploit range
Attack complexity
Authentication
Remote
Low
No required
Confidentiality impact
Integrity impact
Availability impact
Partial
None
None

 References:
http://www.securityfocus.com/bid/105922
https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf

Related CVE
CVE-2019-6584
A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02). The integrated webserver does not invalidate ...
CVE-2019-6571
A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02). An attacker with network access to port 10005...
CVE-2019-6567
A vulnerability has been identified in SCALANCE X-200 (All Versions < V5.2.4), SCALANCE X-200IRT (All versions), SCALANCE X-300 (All versions), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacke...
CVE-2019-10926
A vulnerability has been identified in SIMATIC Ident MV420 family (All versions), SIMATIC Ident MV440 family (All versions). Communication with the device is not encrypted. Data transmitted between the device and the user can be obtained by an attack...
CVE-2019-10925
A vulnerability has been identified in SIMATIC Ident MV420 family (All versions), SIMATIC Ident MV440 family (All versions). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The se...
CVE-2019-6578
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All...
CVE-2019-6577
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 un...
CVE-2019-6576
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 un...