Vulnerability CVE-2018-8850


Published: 2018-09-26

Description:
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result in altered control flow, arbitrary control of a resource, or arbitrary code execution.

Type:

CWE-20

(Improper Input Validation)

CVSS2 => (AV:N/AC:L/Au:N/C:P/I:P/A:P)

CVSS Base Score
Impact Subscore
Exploitability Subscore
7.5/10
6.4/10
10/10
Exploit range
Attack complexity
Authentication
Remote
Low
No required
Confidentiality impact
Integrity impact
Availability impact
Partial
Partial
Partial
Affected software
Philips -> E-alert firmware 

 References:
http://www.securityfocus.com/bid/105194
https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01
https://www.usa.philips.com/healthcare/about/customer-support/product-security