Vulnerability CVE-2019-6575


Published: 2019-04-17

Description:
A vulnerability has been identified in SIMATIC CP443-1 OPC UA (All versions), SIMATIC ET 200 Open Controller CPU 1515SP PC2 (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions), SIMATIC HMI Comfort Panels 4" - 22" (All versions), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC NET PC Software (All versions >= V7.1), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R (All versions < V3.2.1), SIMATIC S7-1500 CPU family (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15-P018), SIMATIC WinCC Runtime Advanced (All versions), SINEC-NMS (All versions), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. At the time of advisory publication no public exploitation of this security vulnerability was known.

Type:

CWE-20

(Improper Input Validation)

Vendor: Siemens
Product: Simatic s7-1500 software controller 
Version: 2.5;
Product: Simatic s7-1500t firmware 
Version: 2.5;
Product: Simatic s7-1500 firmware 
Version: 2.5;
Product: Simatic s7-1500s firmware 
Version: 2.5;
Product: Simatic s7-1500f firmware 
Version: 2.5;
Product: Sinec-nms 
Product: Simatic rf188c firmware 
Product: Telecontrol server basic 
Product: Simatic wincc runtime comfort 
Product: Simatic et 200 open controller cpu 1515sp pc2 firmware 
Product: Simatic wincc runtime mobile 
Product: Simatic net pc software firmware 
Product: Sinema server 
Product: Simatic wincc runtime advanced 
Product: Simatic rf600r firmware 
Product: Simatic cp443-1 opc ua firmware 
Product: Simatic wincc runtime hsp comfort 
Product: Simatic ipc diagmonitor firmware 

CVSS2 => (AV:N/AC:L/Au:N/C:N/I:N/A:C)

CVSS Base Score
Impact Subscore
Exploitability Subscore
7.8/10
6.9/10
10/10
Exploit range
Attack complexity
Authentication
Remote
Low
No required
Confidentiality impact
Integrity impact
Availability impact
None
None
Complete

 References:
https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf

Related CVE
CVE-2019-12261
Wind River VxWorks 6.7 though 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 3 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion during connect() to a remote host.
CVE-2019-12260
Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 2 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion caused by a malformed TCP AO option.
CVE-2019-12258
Wind River VxWorks 6.6 through vx7 has Session Fixation in the TCP component. This is a IPNET security vulnerability: DoS of TCP connection via malformed TCP options.
CVE-2019-12255
Wind River VxWorks 6.6 through 6.9 has a Buffer Overflow in the TCP component (issue 1 of 4). This is a IPNET security vulnerability: TCP Urgent Pointer = 0 that leads to an integer underflow.
CVE-2019-12265
Wind River VxWorks 6.5, 6.6, 6.7, 6.8, 6.9.3 and 6.9.4 has a Memory Leak in the IGMPv3 client component. There is an IPNET security vulnerability: IGMP Information leak via IGMPv3 specific membership report.
CVE-2019-12263
Wind River VxWorks 6.9.4 and vx7 has a Buffer Overflow in the TCP component (issue 4 of 4). There is an IPNET security vulnerability: TCP Urgent Pointer state confusion due to race condition.
CVE-2019-12259
Wind River VxWorks 6.6, 6.7, 6.8, 6.9 and vx7 has an array index error in the IGMPv3 client component. There is an IPNET security vulnerability: DoS via NULL dereference in IGMP parsing.
CVE-2019-12257
Wind River VxWorks 6.6 through 6.9 has a Buffer Overflow in the DHCP client component. There is an IPNET security vulnerability: Heap overflow in DHCP Offer/ACK parsing inside ipdhcpc.

Copyright 2019, cxsecurity.com

 

Back to Top