FLIR AX8 Thermal Camera 1.32.16 Hard-Coded Credentials

2018.10.22
Credit: LiquidWorm
Risk: High
Local: No
Remote: Yes
CVE: N/A
CWE: N/A

# Exploit Title: FLIR AX8 Thermal Camera 1.32.16 - Hard-Coded Credentials # Author: Gjoko 'LiquidWorm' Krstic @zeroscience # Date: 2018-10-14 # Vendor: FLIR Systems, Inc # Product web page: https://www.flir.com # Affected version: Firmware: 1.32.16, 1.17.13, OS: neco_v1.8-0-g7ffe5b3 # Hardware: Flir Systems Neco Board # Tested on: GNU/Linux 3.0.35-flir+gfd883a0 (armv7l), lighttpd/1.4.33, PHP/5.4.14 # References: # Advisory ID: ZSL-2018-5494 # Advisory URL: https://www.zeroscience.mk/en/vulnerabilities/ZSL-2018-5494.php # Desc: The devices utilizes hard-coded and credentials within its Linux distribution # image. These sets of credentials (SSH) are never exposed to the end-user and cannot # be changed through any normal operation of the camera. Attacker could exploit this # vulnerability by logging in using the default credentials for the web panel or gain # shell access. # Hard-coded SSH access: # ---------------------- fliruser:3vlig root:hello # Default web creds: # ------------------ admin:admin user:user viewer:viewer service:??? developer:???