Vulnerability CVE-2019-9201


Published: 2019-02-26   Modified: 2019-02-27

Description:
Phoenix Contact ILC 131 ETH, ILC 131 ETH/XC, ILC 151 ETH, ILC 151 ETH/XC, ILC 171 ETH 2TX, ILC 191 ETH 2TX, ILC 191 ME/AN, and AXC 1050 devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories.

Type:

CWE-287

(Improper Authentication)

Vendor: Phoenixcontact
Product: Ilc 171 eth 2tx firmware 
Product: Axc 1050 firmware 
Product: Ilc 191 me/an firmware 
Product: Ilc 131 eth firmware 
Product: Ilc 151 eth firmware 
Product: Ilc 191 eth 2tx firmware 
Product: Ilc 131 eth/xc firmware 
Product: Ilc 151 eth/xc firmware 

CVSS2 => (AV:N/AC:L/Au:N/C:P/I:P/A:C)

CVSS Base Score
Impact Subscore
Exploitability Subscore
9/10
8.5/10
10/10
Exploit range
Attack complexity
Authentication
Remote
Low
No required
Confidentiality impact
Integrity impact
Availability impact
Partial
Partial
Complete

 References:
https://medium.com/@SergiuSechel/misconfiguration-in-ilc-gsm-gprs-devices-leaves-over-1-200-ics-devices-vulnerable-to-attacks-over-82c2d4a91561

Related CVE
CVE-2019-12870
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Uninitialized Pointer and remote code execution. The attacker need...
CVE-2019-12869
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Out-Of-Bounds Read, Information Disclosure, and remote code execut...
CVE-2019-12871
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to a Use-After-Free and remote code execution. The attacker needs to get...
CVE-2019-10953
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
CVE-2019-9744
An issue was discovered on PHOENIX CONTACT FL NAT SMCS 8TX, FL NAT SMN 8TX, FL NAT SMN 8TX-M, and FL NAT SMN 8TX-M-DMG devices. There is unauthorized access to the WEB-UI by attackers arriving from the same source IP address as an authenticated user,...
CVE-2019-9743
An issue was discovered on PHOENIX CONTACT RAD-80211-XD and RAD-80211-XD/HP-BUS devices. Command injection can occur in the WebHMI component.
CVE-2016-8380
The web server in Phoenix Contact ILC PLCs allows access to read and write PLC variables without authentication.
CVE-2016-8371
The web server in Phoenix Contact ILC PLCs can be accessed without authenticating even if the authentication mechanism is enabled.